107 research outputs found

    Persistent Zika Virus Detection in Semen in a Traveler Returning to the United Kingdom from Brazil, 2016.

    Get PDF
    Zika virus is normally transmitted by mosquitos, but cases of sexual transmission have been reported. We describe a patient with symptomatic Zika virus infection in whom the virus was detected in semen for 92 days. Our findings support recommendations for 6 months of barrier contraceptive use after symptomatic Zika virus infection

    Clinical Validation of a Rapid Variant-Proof RT-RPA Assay for the Detection of SARS-CoV-2

    Get PDF
    The COVID-19 pandemic has unveiled a pressing need to expand the diagnostic landscape to permit high-volume testing in peak demand. Rapid nucleic acid testing based on isothermal amplification is a viable alternative to real-time reverse transcription polymerase chain reaction (RT-PCR) and can help close this gap. With the emergence of SARS-CoV-2 variants of concern, clinical validation of rapid molecular tests needs to demonstrate their ability to detect known variants, an essential requirement for a robust pan-SARS-CoV-2 assay. To date, there has been no clinical validation of reverse transcription recombinase polymerase amplification (RT-RPA) assays for SARS-CoV-2 variants. We performed a clinical validation of a one-pot multi-gene RT-RPA assay with the E and RdRP genes of SARS-CoV-2 as targets. The assay was validated with 91 nasopharyngeal samples, with a full range of viral loads, collected at University College London Hospitals. Moreover, the assay was tested with previously sequenced clinical samples, including eleven lineages of SARS-CoV-2. The rapid (20 min) RT-RPA assay showed high sensitivity and specificity, equal to 96% and 97%, respectively, compared to gold standard real-time RT-PCR. The assay did not show cross-reactivity with the panel of respiratory pathogens tested. We also report on a semi-quantitative analysis of the RT-RPA results with correlation to viral load equivalents. Furthermore, the assay could detect all eleven SARS-CoV-2 lineages tested, including four variants of concern (Alpha, Beta, Delta, and Omicron). This variant-proof SARS-CoV-2 assay offers a significantly faster and simpler alternative to RT-PCR, delivering sensitive and specific results with clinical samples

    Estimating the effectiveness of routine asymptomatic PCR testing at different frequencies for the detection of SARS-CoV-2 infections

    Get PDF
    AbstractBackgroundRoutine asymptomatic testing using RT-PCR of people who interact with vulnerable populations, such as medical staff in hospitals or care workers in care homes, has been employed to help prevent outbreaks among vulnerable populations. Although the peak sensitivity of RT-PCR can be high, the probability of detecting an infection will vary throughout the course of an infection. The effectiveness of routine asymptomatic testing will therefore depend on testing frequency and how PCR detection varies over time.MethodsWe fitted a Bayesian statistical model to a dataset of twice weekly PCR tests of UK healthcare workers performed by self-administered nasopharyngeal swab, regardless of symptoms. We jointly estimated times of infection and the probability of a positive PCR test over time following infection, we then compared asymptomatic testing strategies by calculating the probability that a symptomatic infection is detected before symptom onset and the probability that an asymptomatic infection is detected within 7 days of infection.FindingsWe estimated that the probability that the PCR test detected infection peaked at 77% (54 - 88%) 4 days after infection, decreasing to 50% (38 - 65%) by 10 days after infection. Our results suggest a substantially higher probability of detecting infections 1–3 days after infection than previously published estimates. We estimated that testing every other day would detect 57% (33-76%) of symptomatic cases prior to onset and 94% (75-99%) of asymptomatic cases within 7 days if test results were returned within a day.InterpretationOur results suggest that routine asymptomatic testing can enable detection of a high proportion of infected individuals early in their infection, provided that the testing is frequent and the time from testing to notification of results is sufficiently fast.FundingWellcome Trust, National Institute for Health Research (NIHR) Health Protection Research Unit, Medical Research Council (UKRI)</jats:sec

    Self-sampling kits to increase HIV testing among black Africans in the UK: the HAUS mixed-methods study

    Get PDF
    Background: Timely diagnosis of human immunodeficiency virus (HIV) enables access to antiretroviral treatment, which reduces mortality, morbidity and further transmission in people living with HIV. In the UK, late diagnosis among black African people persists. Novel methods to enhance HIV testing in this population are needed. / Objectives: To develop a self-sampling kit (SSK) intervention to increase HIV testing among black Africans, using existing community and health-care settings (stage 1) and to assess the feasibility for a Phase III evaluation (stage 2). / Design: A two-stage, mixed-methods design. Stage 1 involved a systematic literature review, focus groups and interviews with key stakeholders and black Africans. Data obtained provided the theoretical base for intervention development and operationalisation. Stage 2 was a prospective, non-randomised study of a provider-initiated, HIV SSK distribution intervention targeted at black Africans. The intervention was assessed for cost-effectiveness. A process evaluation explored feasibility, acceptability and fidelity. / Setting: Twelve general practices and three community settings in London. / Main outcome measure: HIV SSK return rate. / Results: Stage 1 – the systematic review revealed support for HIV SSKs, but with scant evidence on their use and clinical effectiveness among black Africans. Although the qualitative findings supported SSK distribution in settings already used by black Africans, concerns were raised about the complexity of the SSK and the acceptability of targeting. These findings were used to develop a theoretically informed intervention. Stage 2 – of the 349 eligible people approached, 125 (35.8%) agreed to participate. Data from 119 were included in the analysis; 54.5% (65/119) of those who took a kit returned a sample; 83.1% of tests returned were HIV negative; and 16.9% were not processed, because of insufficient samples. Process evaluation showed the time pressures of the research process to be a significant barrier to feasibility. Other major barriers were difficulties with the SSK itself and ethnic targeting in general practice settings. The convenience and privacy associated with the SSK were described as beneficial aspects, and those who used the kit mostly found the intervention to be acceptable. Research governance delays prevented implementation in Glasgow. / Limitations: Owing to the study failing to recruit adequate numbers (the intended sample was 1200 participants), we were unable to evaluate the clinical effectiveness of SSKs in increasing HIV testing in black African people. No samples were reactive, so we were unable to assess pathways to confirmatory testing and linkage to care. / Conclusions: Our findings indicate that, although aspects of the intervention were acceptable, ethnic targeting and the SSK itself were problematic, and scale-up of the intervention to a Phase III trial was not feasible. The preliminary economic model suggests that, for the acceptance rate and test return seen in the trial, the SSK is potentially a cost-effective way to identify new infections of HIV. / Future work: Sexual and public health services are increasingly utilising self-sampling technologies. However, alternative, user-friendly SSKs that meet user and provider preferences and UK regulatory requirements are needed, and additional research is required to understand clinical effectiveness and cost-effectiveness for black African communities. / Study registration: This study is registered as PROSPERO CRD42014010698 and Integrated Research Application System project identification 184223. / Funding: The National Institute for Health Research Health Technology Assessment programme and the BHA for Equality in Health and Social Care

    Hepatitis delta virus testing, epidemiology and management: A multicentre cross-sectional study of patients in London

    Get PDF
    AbstractBackgroundHepatitis delta virus (HDV) testing is recommended for all patients with hepatitis B virus (HBV) infection. HDV infection is associated with severe liver disease and interferon is the only available treatment.ObjectivesTo determine the rate of anti-HDV antibody testing in HBV patients; and to describe the epidemiology, clinical characteristics and management of HDV-infected patients at four hospitals in London.Study designThe anti-HDV testing rate was estimated by reviewing clinical and laboratory data. Cross-sectional data collection identified HDV-infected patients who had attended the study centres between 2005 and 2012.ResultsAt a centre with clinic-led anti-HDV testing, 40% (67/168) of HBV patients were tested. Recently diagnosed HBV patients were more likely to be screened than those under long-term follow-up (62% vs 36%, P=0.01). At a centre with reflex laboratory testing, 99.4% (3543/3563) of first hepatitis B surface antigen positive samples were tested for anti-HDV. Across the four study centres there were 55 HDV-infected patients, of whom 50 (91%) had immigrated to the UK and 27 (49%) had evidence of cirrhosis. 31 patients received interferon therapy for HDV with an end of treatment virological response observed in 10 (32%).ConclusionsThe anti-HDV testing rate was low in a centre with clinic-led testing, but could not be evaluated in all centres. The HDV-infected patients were of diverse ethnicity, with extensive histological evidence of liver disease and poor therapeutic responses. Future recommendations include reflex laboratory testing algorithms and a prospective cohort study to optimise the investigation and management of these patients

    Management of hepatitis B in pregnant women and infants: a multicentre audit from four London hospitals.

    Get PDF
    BACKGROUND: Pregnant women with hepatitis B virus (HBV) infection can transmit the infection to their infants, screening of patients and appropriate interventions reduce vertical transmission. This audit was conducted to assess adherence to the national guidelines for management of HBV infection in pregnancy. METHODS: A retrospective audit was conducted on pregnant women diagnosed with hepatitis B on screening in antenatal clinics, across four hospitals in London over 2 years (2009-2010). Data was collected from antenatal records and discharge summaries using a standard audit form. The outcomes measured included HBV serological markers, HBV DNA, detection of other blood borne viruses and referral to hepatology services, administration of active and passive prophylaxis to infants at birth. Descriptive statistics are presented. Proportions were compared using the χ2 test and 95% confidence intervals (CI) were calculated for prevalence estimates. Analyses were conducted using STATA 12. RESULTS: HBsAg was detected in 1.05% (n = 401, 95% CI 0.95-1.16) of women attending an antenatal appointment, 12% (n = 48) of the women were at a high risk of vertical transmission (HBe Ag positive or antiHBe and HBeAg negative or HBV DNA >106 IU/ml). Only 62% (n = 248) women were referred to hepatology or specialist clinics and 29% (n = 13) of women of high infectivity were on antiviral agents. Testing for hepatitis C and delta virus was suboptimal. 75% (n = 36) of the infants at a high risk of acquisition of HBV received both active and passive prophylaxis. CONCLUSION: In certain sectors of London, implementation of the pathway for management of women with hepatitis B and their infants is suboptimal. National guidelines should be followed and improved intersectorial sharing of information is needed to reduce the risk of women of high infectivity being lost to follow up

    An interactive data visualisation application to investigate nosocomial transmission of infections

    Get PDF
    Background: Healthcare-associated infections represent a major threat to patient, staff and visitor safety. Identification of episodes that are likely to have resulted from nosocomial transmission has important implications for infection control. Routinely collected data on ward admissions and sample dates, combined with pathogen genomic information could provide useful insights. We describe a novel, open-source, application for visualising these data, and demonstrate its utility for investigating nosocomial transmission using a case study of a large outbreak of norovirus infection. Methods: We developed the application using Shiny, a web application framework for R. For the norovirus case study, cases were defined as patients who had a faecal sample collected at the hospital in a winter season that tested positive for norovirus. Patient demographics and ward admission dates were extracted from hospital systems. Detected norovirus strains were genotyped and further characterised through sequencing of the hypervariable P2 domain. The most commonly detected sub-strain was visualised using the interactive application. Results: There were 156 norovirus-positive specimens collected from 107 patients. The most commonly detected sub-strain affected 30 patients in five wards. We used the interactive application to produce three visualisations: a bar chart, a timeline, and a schematic ward plan highlighting plausible transmission links. Visualisations showed credible links between cases on the elderly care ward. Conclusions: Use of the interactive application provided insights into transmission in this large nosocomial outbreak of norovirus, highlighting where infection control practices worked well or could be improved. This is a flexible tool that could be used for investigation of any infection in any hospital by interactively changing parameters. Challenges include integration with hospital systems for extracting data. Prospective use of this application could inform better infection control in real time.</ns4:p

    A fast extraction-free isothermal LAMP assay for detection of SARS-CoV-2 with potential use in resource-limited settings

    Get PDF
    BACKGROUND: To retain the spread of SARS-CoV-2, fast, sensitive and cost-effective testing is essential, particularly in resource limited settings (RLS). Current standard nucleic acid-based RT-PCR assays, although highly sensitive and specific, require transportation of samples to specialised laboratories, trained staff and expensive reagents. The latter are often not readily available in low- and middle-income countries and this may significantly impact on the successful disease management in these settings. Various studies have suggested a SARS-CoV-2 loop mediated isothermal amplification (LAMP) assay as an alternative method to RT-PCR. METHODS: Four previously published primer pairs were used for detection of SARS-CoV-2 in the LAMP assay. To determine optimal conditions, different temperatures, sample input and incubation times were tested. Ninety-three extracted RNA samples from St. George's Hospital, London, 10 non-extracted nasopharyngeal swab samples from Great Ormond Street Hospital for Children, London, and 92 non-extracted samples from Queen Elisabeth Central Hospital (QECH), Malawi, which have previously been tested for SARS-Cov-2 by quantitative reverse-transcription RealTime PCR (qRT-PCR), were analysed in the LAMP assay. RESULTS: In this study we report the optimisation of an extraction-free colourimetric SARS-CoV-2 LAMP assay and demonstrated that a lower limit of detection (LOD) between 10 and 100 copies/µL of SARS-CoV-2 could be readily detected by a colour change of the reaction within as little as 30 min. We further show that this assay could be quickly established in Malawi, as no expensive equipment is necessary. We tested 92 clinical samples from QECH and showed the sensitivity and specificity of the assay to be 86.7% and 98.4%, respectively. Some viral transport media, used routinely to stabilise RNA in clinical samples during transportation, caused a non-specific colour-change in the LAMP reaction and therefore we suggest collecting samples in phosphate buffered saline (which did not affect the colour) as the assay allows immediate sample analysis on-site. CONCLUSION: SARS-CoV-2 LAMP is a cheap and reliable assay that can be readily employed in RLS to improve disease monitoring and management

    Distinct Metabolic Requirements of Exhausted and Functional Virus-Specific CD8 T Cells in the Same Host.

    Get PDF
    T cells undergo profound metabolic changes to meet the increased energy demands of maintaining an antiviral response. We postulated that differences in metabolic reprogramming would shape the efficacy of CD8 T cells mounted against persistent viral infections. We found that the poorly functional PD-1(hi) T cell response against hepatitis B virus (HBV) had upregulated the glucose transporter, Glut1, an effect recapitulated by oxygen deprivation to mimic the intrahepatic environment. Glut1(hi) HBV-specific T cells were dependent on glucose supplies, unlike the more functional cytomegalovirus (CMV)-specific T cells that could utilize oxidative phosphorylation in the absence of glucose. The inability of HBV-specific T cells to switch to oxidative phosphorylation was accompanied by increased mitochondrial size and lower mitochondrial potential, indicative of mitochondrial dysfunction. Interleukin (IL)-12, which recovers HBV-specific T cell effector function, increased their mitochondrial potential and reduced their dependence on glycolysis. Our findings suggest that mitochondrial defects limit the metabolic plasticity of exhausted HBV-specific T cells.A.S., J.W., and M.K.M. are funded by a Wellcome Trust Senior Investigator Award (to M.K.M.); L.J.P. and M.K.M. are funded by MRC Project grant no. MR/M020126/; I.O. is funded by an EASL post-doctoral fellowship; U.S.G. is funded by the Wellcome Trust Clinical Research Training Fellowship; and N.H. and P.T.K. are funded by a grant from Barts and The London Charity. A.S. was also funded by a UCLH CIDC/NIHR Fast Track Grant, and D.J. was funded by the Wolfson Foundation.This is the final version of the article. It first appeared from Elsevier via http://dx.doi.org/10.1016/j.celrep.2016.06.07

    Early and Highly Suppressive ART are Main Factors Associated with Low Viral Reservoir in European Perinatally HIV Infected Children

    Get PDF
    Abstract BACKGROUND: Future strategies aiming to achieve HIV-1 remission are likely to target individuals with small reservoir size. SETTING: We retrospectively investigated factors associated with HIV-1 DNA levels in European, perinatally HIV-infected children starting ART <6 months of age. METHODS: Total HIV-1 DNA was measured from 51 long-term suppressed children 6.3 years (median) after initial viral suppression. Factors associated with log10 total HIV-1 DNA were analyzed using linear regression. RESULTS: At ART initiation, children were aged median [IQR] 2.3 [1.2,4.1] months, CD4% 37 [24,45] %, CD8% 28 [18,36] %, log10 plasma viral load (VL) 5.4 [4.4,5.9] copies/ml. Time to viral suppression was 7.98 [4.6,19.3] months. Following suppression, 13 (25%) children had suboptimal response [ 652 consecutive VL50-400 followed by VL<50] and/or experienced periods of virological failure [ 652 consecutive VL 65400 followed by VL<50]. Median total HIV-1 DNA was 43 [6,195] copies/10 PBMC.Younger age at therapy initiation was associated with lower total HIV-1 DNA (adjusted coefficient [AC] 0.12 per month older, p=0.0091), with a month increase in age at ART start being associated with a 13% increase in HIV DNA. Similarly, a higher proportion of time spent virally suppressed (AC 0.10 per 10% higher, p=0.0022) and absence of viral failure/suboptimal response (AC 0.34 for those with fail/ suboptimal response, p=0.0483) were associated with lower total HIV-1 DNA. CONCLUSION: Early ART initiation and a higher proportion of time suppressed are linked with lower total HIV-1 DNA. Early ART start and improving adherence in perinatally HIV-1 infected children minimize the size of viral reservoir.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal
    • …
    corecore